60 KV Power Generator
A standard 60 kVA backup diesel generator typically delivers 60 kVA of prime power (and around 66 kVA standby power) across a 3-phase, 400V configuration to support commercial and industrial buildings
Description
A 60 kVA silent generator is a highly efficient power solution ideal for small-to-medium businesses, clinics, petrol stations, and luxury residential estates. It delivers approximately 48 kW of power (assuming a standard 0.8 power factor), making it the go-to size for operations that require robust commercial-grade power without the massive physical footprint of larger industrial units.
1. Advanced Sound Attenuation & Canopy
- Acoustic Performance: Encased in a specialized acoustic canopy that limits operational noise to 63 to 70 dBA at 7 meters , allowing it to run smoothly in residential or noise-sensitive commercial zones.
- Sound Dampening: Lined with high-density, fire-retardant acoustic foam and equipped with internal air-baffle systems that dissipate engine noise while optimizing cooling airflow.
- Weatherproof Protection: Built using heavy-duty galvanized steel panels with anti-corrosion powder coatings and stainless steel hardware to withstand harsh outdoor elements.
- Exhaust Silencing: Features an internal, heavy-duty residential muffler that significantly dampens exhaust notes.
2. Engine and Fuel Dynamics
- Compact Diesel Engine: Usually driven by a reliable, water-cooled 4-cylinder diesel engine (such as Perkins, Cummins, or Deutz) known for high thermal efficiency and durability.
- Integrated Fuel Base: Built with an internal base fuel tank, typically ranging from 120 to 150 liters in capacity.
- Operational Runtime: Consumes roughly 9 to 11 liters of fuel per hour at 75% load, providing 12 to 15 hours of continuous runtime on a single fill.
3. Electrical & Control Specifications
- Clean Power Delivery: Features a high-performance brushless alternator equipped with an Automatic Voltage Regulator (AVR) to maintain voltage stability within ±1%, ensuring it is safe for servers, computers, and medical equipment.
- Dual Voltage Configuration: Offers standard 3-phase output (e.g., 415/240V) alongside single-phase configurations to handle mixed electrical loads seamlessly.
- Digital Management Panel: Managed via an intelligent control module (such as Deep Sea Electronics) displaying real-time metrics like voltage, frequency, running hours, engine temperature, and fuel levels.
- Mains Failure Ready: Fully compatible with an Automatic Transfer Switch (ATS) to trigger autonomous starting and load transfer within seconds of a grid power outage.
4. Safety and Maintenance Features
- Auto-Protection Systems: Programmed with automatic critical shutdown triggers for low oil pressure, high engine temperature, over/under speed, and voltage irregularities.
- Accessible Maintenance: Designed with large, lockable, side-opening canopy doors that provide quick, unhindered access to the oil dipstick, filters, battery, and radiator cap.
- Safe Logistics: Outfitted with an integrated Molded Case Circuit Breaker (MCCB), an external emergency stop button, reinforced base forklift pockets, and a central top-lifting hook for easy transport.
Specification
| Parameter | Specification Details |
|---|---|
| Power Factor | 0.8 (lagging) |
| Governor Type | Electronic |
| Rated Voltage | 400V / 230V (or 380V–415V) |
| Cooling System | Water-cooled / Radiator |
| Engine Details | Aspiration Turbocharged |
| Fuel Consumption | ~18 Liters/hour at 100% Prime Load |
| Insulation Class | Class H |
| Frequency / Speed | 50 Hz @ 1500 RPM (or 60 Hz @ 1800 RPM) |
| Alternator Details | Excitation Type Brushless, Self-excited |
| Amperage (at 400V) | ~115 Amps per phase |
| Approximate Weight | 1,350 kg to 1,700 kg (dry) |
| Fuel Tank Capacity | 150 to 220 Liters (integrated base tank) |
| Voltage Regulation | Automatic Voltage Regulator (AVR) |
| Electrical / Output | Prime Power Rating 80 kVA / 64 kW |
| Phase Configuration | 3-Phase, 4-Wire |
| Physical (Enclosed) | Noise Level (Silent Canopy) 65 to 72 dB(A) at 7 meters |
| Run Time (Base Tank) | Minimum 8 hours at full load |
| Standby Power Rating | 88 kVA / 70.4 kW |
| Fuel & Operations | Fuel Type Diesel |
| Cylinder Configuration | 4 cylinders, vertical in-line |
| Dimensions (L x W x H) | ~2,500mm x 1,000mm x 1,550mm |
| Specification Category | Parameter Typical Standard Value |
| Key Specifications for an | 80 kVA Generator |
Related Products

A 100 kVA silent generator is an industrial-grade power solution designed to provide reliable prime or emergency standby power while minimizing acoustic disruption. These units are heavily utilized across commercial properties, manufacturing hubs, data centers, and health facilities.

Power Generator 40 KVA A standard 40 kVA backup generator delivers about 32 kW of real power and is designed to provide reliable emergency or prime power for small commercial buildings, offices, and large properties.

An 80 kVA silent generator is a versatile power unit optimized for medium-sized commercial buildings, construction sites, agricultural operations, and backup infrastructure. It fills the gap between light commercial and heavy industrial power needs, delivering roughly 64 kW of electrical power (at a standard 0.8 power factor).