100 KVA Power Generator
A 100 kVA silent generator is an industrial-grade power solution designed to provide reliable prime or emergency standby power while minimizing acoustic disruption. These units are heavily utilized across commercial properties, manufacturing hubs, data centers, and health facilities.
Description
A 100 kVA silent generator is an industrial-grade power solution designed to provide reliable prime or emergency standby power while minimizing acoustic disruption. These units are heavily utilized across commercial properties, manufacturing hubs, data centers, and health facilities.
The critical features defining a high-quality 100 kVA silent generator span acoustic protection, advanced control systems, mechanical capability, and safety features:
1. Sound-Attenuated Enclosure (Silent Canopy)
- Acoustic Insulation: Enclosed in high-density soundproofing foam and a specialized canopy that reduces operating noise to roughly 66 to 75 dBA at 7 meters , mimicking the volume of a normal conversational tone.
- Weatherproof Construction: Typically built with heavy-duty galvanized steel or anti-corrosive aluminum finished with UV-resistant powder coat paint for reliable outdoor placement.
- Airflow Optimization: Intricate internal baffles and an integrated residential-grade exhaust silencer designed to restrict sound while preventing engine overheating.
2. Digital Control Systems & Automation
- Intelligent Controller: Equipped with an advanced digital module—such as a Deep Sea Electronics (DSE), SmartGen, or Fortrust controller—featuring a digital viewing window to monitor output metrics, load levels, fuel consumption, and error diagnostics.
- ATS Configuration: Ready for integration with an Automatic Transfer Switch (ATS) , allowing the generator to autonomously start and assume the load within seconds of a main power failure.
- Auto-Shutdown Protections: Includes self-diagnostic fail-safes that trigger an automatic shutdown during critical faults like low oil pressure, high water temperature, over-speeding, or circuit overloads.
3. Electrical and Engine Engineering
- Three-Phase Output: Delivers standard 3-phase commercial and industrial voltage configurations (typically 415V or 120/208V to 277/480V) to run heavy machinery, elevators, HVAC units, and electronic appliances.
- Automatic Voltage Regulation (AVR): Constantly modulates and smooths electrical output to protect sensitive commercial computers and laboratory systems from voltage spikes.
- Dual Power Ratings: Designed to provide roughly 100 kVA of continuous Prime Power (PRP) or up to 110 kVA for short-duration Standby Power (LTP) emergencies.
- Fuel Capacity: Built with an integrated high-capacity base fuel tank (typically 200–250 liters) providing roughly 14 to 15 hours of continuous runtime under a standard 75% load profile.
4. Maintenance, Safety, and Handling Features
- Ergonomic Access: Outfitted with wide, lockable hinged side doors that permit easy maintenance access to core oil filters, air filters, and mechanical assemblies.
- Physical Mobility Hooks: Engineered with heavy-duty base fork-lift pockets and top-mounted central lifting hooks for crane rigging and structural deployment.
- Safety Hardware: Built with an externally mounted Emergency Stop Button, an integrated battery isolator switch, a robust circuit breaker (such as a molded case circuit breaker - MCCB), and dedicated electrical ground
Specification
| Parameter | Specification Details |
|---|---|
| Parameter | Standard Specification Details / Notes |
| Aspiration | Turbocharged & Intercooled Boosts efficiency and power output |
| Engine Type | 4-cylinder, In-line, 4-stroke Direct-injection diesel engine |
| Displacement | ~4.4 L to 4.8 L Varies by manufacturer (e.g., Perkins or JCB) |
| Power Factor | 0.8 (lagging) Standard industry industrial scale rating |
| Control Panel | Digital Microprocessor Auto mains failure (AMF), shutdown warnings |
| Governor Type | Electronic Governor Ensures precise fuel injection and frequency |
| Rated Current | ~139 Amps Calculated at 415V, 3-phase, 0.8 PF |
| Rated Voltage | 380V – 415V (Three Phase) Region-dependent (e.g., 400V / 230V) |
| Cooling System | Water Cooled / Radiator Set-mounted tropical duty radiator up to 50°C |
| Alternator Type | Brushless, Rotating Field Solid-state electronic voltage regulator (AVR) |
| Rated Frequency | 50 Hz or 60 Hz 1500 RPM for 50Hz / 1800 RPM for 60Hz |
| Insulation Class | Class H Standard protection against temperature rise |
| Approximate Weight | 1,600 kg – 1,700 kg (Wet) Including lube oil and coolant |
| Prime Power Rating | 100 kVA / 80 kW Continuous running at variable load |
| Typical Dimensions | ~2,660 to 3,000 mm (Length) , ~1,100 to 1,350 mm (Width) , ~1,790 to 1,885 mm (Height), Varies based on the style of the silent canopy |
| Sound Level (Silent) | 65 – 68 dB(A) @ 7 meters Equipped with soundproof/weatherproof canopy |
| Standby Power Rating | 110 kVA / 88 kW Emergency power backup (no overload) |
Related Products

Power Generator 40 KVA A standard 40 kVA backup generator delivers about 32 kW of real power and is designed to provide reliable emergency or prime power for small commercial buildings, offices, and large properties.

A standard 60 kVA backup diesel generator typically delivers 60 kVA of prime power (and around 66 kVA standby power) across a 3-phase, 400V configuration to support commercial and industrial buildings

An 80 kVA silent generator is a versatile power unit optimized for medium-sized commercial buildings, construction sites, agricultural operations, and backup infrastructure. It fills the gap between light commercial and heavy industrial power needs, delivering roughly 64 kW of electrical power (at a standard 0.8 power factor).